Modelo: YW-1146
Marca: OEM, marca ODM
Certificación: CSA
Soporte De Personalización: OEM, ODM
Lugar De Origen: Porcelana
Paquete: empacación de paletas
productividad: 50pcs/month
transporte: Ocean,Land,Air,Express,Railway
Lugar de origen: Foshan, Guangdong, China
Apoyo sobre: 50pcs/month
Certificados : TUV.ITS.CSA.BV.SGS .CNAS
Hafen: Shenzhen,Hongkong,Guangzhou
Tipo de Pago: T/T,Paypal,Western union
Incoterm: FOB,CIF,EXW,DDP
Spray nozzle tester para la prueba anti -w atter s de oración
YW-1146
Normas:
L GB4208-2008 (IEC 60529) "Grados de protección proporcionados por recintos (código IP)" IPX5 e IPX6
L GB2099.1 (IEC 60884-1)
L GB4706.1 (IEC 60335-1)
L GB7000.1 (IEC 60598-1)
L GB/T 4942.1-2006 "Grados de protección proporcionados por la estructura integral de las máquinas eléctricas giratorias (código IP)"
L GB/T 4942.2-1993 "Grados de protección proporcionados por el recinto de la aparemadura de bajo voltaje"
L QC/T 413-2002 "Condiciones técnicas básicas para equipos eléctricos automotrices"
Solicitud:
Un pplicable para realizar pruebas IPX5 e IPX6 en productos.
Prueba en:
Tales como electrodomésticos, accesorios de iluminación, gabinetes eléctricos, componentes eléctricos, automóviles automotrices, productos eléctricos de motocicletas (como instrumentos automotrices, varios interruptores, micro motores, etc.)
Funcionalidad:
Con medidor de presión, coincidencia única para cambiar la cabeza del rociador, lo que puede coincidir con un conjunto completo de sistema impermeable
Parámetros técnicos :
Model |
YW-1146-1 |
YW-1146-2 |
Parameter items |
IPX5 |
IPX6 |
Nozzle aperture |
Ф 6.3mm |
Ф 12.5mm |
Discharge |
12.5 ± 0.625L/min, adjustable flow meter |
100 ± 5 L/min, adjustable flow meter |
Distance between nozzle and shell |
2.5-3m |
|
Test time |
Not less than 1min/m ² (But not less than 3 minutes) |
|
Pressure gauge |
0~0.25MPa |
|
Test Site requirements |
A dedicated IP waterproof testing room with a width greater than 3m, with good water inlet and drainage functions, and wall installation |
|
Water sources |
IP5 test:clean, impurity-free water,water flow rate greater than 12.5 L/min±5% IP6 test:clean, impurity-free water,water flow rate greater than 100 L/min±5% The IP5 and IP6 tests are to be conducted using a stainless steel water storage tank and pressurizing equipment. |